Prototyping service
custom designs tuned to your needs
  • From 1 to 5 compartmentalized deposition chambers
  • High connectivity bidirectional connections between chambers
  • Fast developpment process with high quality standards
  • Total of 45 prototyped chips – 3 iterations for possible design updates

Standard neurofluidic chips

PDMS based for long neural culture (up to 3 months),
all neural or glial cells types,
standardized dimensions for reproducibility.
#
DUAL 10k deposition chamber
  • Up to 10 000 neurons in one chamber
  • Two independant chamber in one chip
  • From 1000 to 5000 cells/mm²
  • Suitable for toxicity assays and functional recordings
reference NF_1_CD_10_2
#
DUAL 50k deposition chamber
  • Up to 50 000 neurons in one chamber
  • Two independant chamber in one chip
  • From 1000 to 5000 cells/mm²
  • Suitable for toxicity assays and functional recordings
reference NF_1_CD_50_1
#
DUAL 100k deposition chamber
  • Up to 100 000 neurons in one chamber
  • Two independant chamber in one chip
  • From 1000 to 5000 cells/mm²
  • Suitable for toxicity assays and functional recordings
reference NF_1_CD_100_3
#
1M deposition chamber
  • Up to 1 000 000 neurons in one chamber
  • From 1000 to 5000 cells/mm²
  • Suitable for toxicity assays and functional recordings
reference NF_1_CD_1000_2
#
Triangular chamber
  • Two compartments interconnected
  • From 1000 to 5000 cells/mm²
  • Suitable for growth kinetics and transport mechanism studies
reference NF_2_X_TR_3
#
100k-10k deposition chamber
  • Up to 100 000 neurons in one chamber and 10 000 in the other
  • High bidirectional connection between chambers
  • From 1000 to 5000 cells/mm² per chamber
  • Suitable for transport mechanism and functional recordings
reference NF_2_CD_100-10_1

In partnership with XONA

#
XC150
  • XonaChip™ (150 µm microgroove barrier)
  • Cat.No: XC150
  • New Plastic Chip!
  • Pre-Assembled!
  • Pre-Bonded!
  • Optically Transparent
  • Size: 75 mm x 25mm
#
XC450
  • XonaChip™ (450 µm microgroove barrier)
  • Cat.No: XC450
  • New Plastic Chip!
  • Pre-Assembled!
  • Pre-Bonded!
  • Optically Transparent
  • Size: 75 mm x 25mm
#
XC900
  • XonaChip™ (900 µm microgroove barrier)
  • Cat.No: XC900
  • New Plastic Chip!
  • Pre-Assembled!
  • Pre-Bonded!
  • Optically Transparent
  • Size: 75 mm x 25mm
#
SND150
  • Standard Neuron Device (150 μm microgroove barrier)
  • Each box contains (5) Silicone Devices
  • Silicone Device
  • Cat.No: SND150
  • Size: ~ 22 mm – ~23mm
#
SND450
  • Standard Neuron Device (450 μm microgroove barrier)
  • Each box contains (5) Silicone Devices
  • Silicone Device
  • Cat.No: SND450
  • Size: ~ 22 mm – ~23mm
#
SND900
  • Standard Neuron Device (900 μm microgroove barrier)
  • Each box contains (5) Silicone Devices
  • Silicone Device
  • Cat.No: SND900
  • Size: ~ 22 mm – ~23mm

CR0 2.0
Fast and multiplexed microfluidic based screening service

  • Alzheimer
  • Intoxication with  Amyloid beta peptide (Aβ42)
  • Rodent primary neurons (hippocampal)
  • Neuro-inflammatory response
  • Network level response (structure and function)
  • Parkinson 
  • Intoxication with 6-OHDA
  • Rodent primary neurons (dopaminergic)
  • Network level response (structure and function)
Readouts : toxicity, synaptogensis, transport / growth rates and functional network activity analysis